Cooling Tower Systems has manufactured cooling tower lines and
related equipment for over 40 years, with five different models in
production. We are the oldest, full service fiberglass cooling tower
manufacturer in business today. All CTS cooling towers are
designed, engineered and tested by our own factory research and
development laboratory. Our towers are second to none in quality and
energy efficiency, and produce a lower total cost of ownership than any
comparable cooling tower solution.
The fiberglass construction of a CTS cooling tower makes the tower
durable, while also making it unmatched time and time again in price.
The lighter weight of a fiberglass tower enables a smaller, more
energy-efficient fan motor to be used...a cost savings from the moment
it is in use.
For Assistance Please Call 800-248-2779 or 830-220-2440
The CTS T25 cooling tower has a nominal tonnage of 5 tons. Our 1/6 HP fan motor creates an air volume of 2118 cu. ft per min. The T25 cooling tower has a nominal water flow of 15 gallons per minute. 52" in height 33 1/2" diameter.
|
The CTS T28 cooling tower has a nominal tonnage of 8 tons. Our 1/6 HP fan motor creates an air volume of 2648 cu. ft per min. The T28 cooling tower has a nominal water flow of 23 gallons per minute. 56" in height 33 1/2" diameter.
|
The CTS T210 cooling tower has a nominal tonnage of 10 tons. Our 1/4 HP fan motor creates an air volume of 3531 cu. ft per min. The T210 cooling tower has a nominal water flow of 30 gallons per minute. 54" in height 41 3/4" diameter.
|
The CTS T215 cooling tower has a nominal tonnage of 15 tons. Our 1/4 HP fan motor creates an air volume of 4767 cu. ft per min. The T215 cooling tower has a nominal water flow of 44 gallons per minute. 59" in height 46" diameter.
|
The CTS LBCS-15LN low noise cooling tower has a nominal tonnage of 15 tons. Our 1/4 HP fan motor creates an air volume of 4767 cu. ft per min. The T215 cooling tower has a nominal water flow of 51.5 gallons per minute. 76" in height 46" diameter.
|
The CTS T220 cooling tower has a nominal tonnage of 20 tons. Our 1/2 HP fan motor creates an air volume of 6356 cu. ft per min. The T220 cooling tower has a nominal water flow of 58 gallons per minute. 63" in height 54 3/8" diameter.
|
The CTS T225 cooling tower has a nominal tonnage of 25 tons. Our 3/4 HP fan motor creates an air volume of 7000 cu. ft per min. The T225 cooling tower has a nominal water flow of 73 gallons per minute. 70 15/16" in height 54 3/8" diameter.
|
Overnite Supplies T230 cooling tower has a nominal tonnage of 30 tons. Our 1 HP fan motor creates an air volume of 8100 cu. ft per min. The T230 cooling tower has a nominal water flow of 88 gallons per minute. 68 3/8" in height 62 1/4" diameter.
|
Overnite Supplies T240 cooling tower has a nominal tonnage of 40 tons. Our 1 1/2 HP fan motor creates an air volume of 9800 cu. ft per min. The T240 cooling tower has a nominal water flow of 118 gallons per minute. 74 1/2" in height 71 5/8" diameter.
|
Overnite Supplies T250 cooling tower has a nominal tonnage of 50 tons. Our 1 1/2 HP fan motor creates an air volume of 11500 cu. ft per min. The T250 cooling tower has a nominal water flow of 148 gallons per minute. 74 1/2" in height 78 3/4" diameter.
|
CTS T260 cooling tower has a nominal tonnage of 60 tons. Our 1 1/2 HP fan motor creates an air volume of 14700 cu. ft per min. The T260 cooling tower has a nominal water flow of 177 gallons per minute. 74 11/16" in height 78 3/4" diameter.
|
Overnite Supplies T270 cooling tower has a nominal tonnage of 70 tons. Our 1 1/2 HP fan motor creates an air volume of 17500 cu. ft per min. The T270 cooling tower has a nominal water flow of 207 gallons per minute. 79 3/8" in height 85 5/8" diameter.
|
CTS T280 cooling tower has a nominal tonnage of 80 tons. Our 2 HP fan motor creates an air volume of 18900 cu. ft per min. The T280 cooling tower has a nominal water flow of 237 gallons per minute. 79 3/8" in height 85 5/8" diameter.
|
The CTS T2100 cooling tower has a nominal tonnage of 100 tons. Our 3 HP fan motor creates an air volume of 24500 cu. ft per min. The T2100 cooling tower has a nominal water flow of 295 gallons per minute. 85 1/16" in height 104 3/8" diameter.
|
The CTS T2125 cooling tower has a nominal tonnage of 125 tons. Our 3 HP fan motor creates an air volume of 29060 cu. ft per min. The T2125 cooling tower has a nominal water flow of 369 gallons per minute. 87" in height 120 1/8" diameter.
|
The CTS T2150 cooling tower has a nominal tonnage of 150 tons. Our 5 HP fan motor creates an air volume of 33260 cu. ft per min. The T2150 cooling tower has a nominal water flow of 446 gallons per minute. 90" in height 130" diameter.
|
The CTS T2175 cooling tower has a nominal tonnage of 175 tons. Our 5 HP fan motor creates an air volume of 40250 cu. ft per min. The T2175 cooling tower has a nominal water flow of 518 gallons per minute. 97 7/8" in height 130" diameter.
|
The CTS T2200 cooling tower has a nominal tonnage of 200 tons. Our 5 HP fan motor creates an air volume of 43760 cu. ft per min. The T2200 cooling tower has a nominal water flow of 592 gallons per minute. 117 3/4" in height 148 3/8" diameter.
|
16-01-80 Fan motor for T-280 cooling tower. This motor will fit a T-280 80 ton cooling tower that has a motor frame # 112M. It is 2 horsepower and can be wired 220 or 440 volt 3 phase.
|
1ST1C5F4 1/2 horsepower Goulds centrifugal stainless steel pump, 230/460V/60 hrtz/3 phase, 24 GPM @35' TDH. Series NPE, end suction, close coupled.
|
LSF-080 Fan blade for CTS T-220 20 ton cooling tower. 30 1/4" diameter.
|
3ST1H2B2 Goulds pump 30 psi (69.3 total head) 24 gpm, 3 horsepower, 3500 RPM, 230/460 volt 3 phase 60 Hrtz.
|
12-01-15 Sprinkler head for CTS T-215 15 ton cooling tower.
|
05-06-15 Hand hole cover for CTS T-215 15 ton cooling tower.
|